### Setting the holiday date range
- The date you set as the end of the holiday includes the holiday duration, **the system returns to its normal routine operation the day after the date range**.
### Checking/unchecking DHW and heating
- Checked
- Heating will operate, but at the reduced temperatures as set in holiday mode.
- DHW (and legionella cycle) will operate but at the reduced temperature--the tank reheats when the temperature falls below 35oc, the schedule is ignored.
- Unchecked
- Heating will be off completely
- DHW will be off completely