### Setting the holiday date range
|
|
|
|
- The date you set as the end of the holiday includes the holiday duration, **the system returns to its normal routine operation the day after the date range**.
|
|
|
|
### Checking/unchecking DHW and heating
|
|
|
|
- Checked
|
|
- Heating will operate, but at the reduced temperatures as set in holiday mode.
|
|
- DHW (and legionella cycle) will operate but at the reduced temperature--the tank reheats when the temperature falls below 35oc, the schedule is ignored.
|
|
- Unchecked
|
|
- Heating will be off completely
|
|