@@ -0,0 +1,22 @@
|
||||
---
|
||||
category:
|
||||
- "[[Journal]]"
|
||||
type:
|
||||
- "[[Log]]"
|
||||
topic:
|
||||
- "[[91 Meigh Road Heating and DHW]]"
|
||||
title: Changing from z2 to z1 ashp
|
||||
created: 2026-01-10T07:56:49
|
||||
date: 2026-01-10
|
||||
---
|
||||
Dip switch settings on [[Mitsubishi FTC6 and 210L Pre-Plumbed Standard Cylinder]]
|
||||
• SW3-6 (2-zone valve ON/OFF control): from ON to OFF
|
||||
• SW2-7 (2-zone temperature control): OFF (already off, this is flow temp control)
|
||||
|
||||
Installed zone 1 [[ESPHome Ecodan heatpump]] firmware on to device and started @ ~0800
|
||||
|
||||
I had noticed that there is two remaining control entities in the [[Home Assistant]] setting
|
||||
- Auto-Adaptive: Min. Heating Flow Temperature z2
|
||||
- Auto-Adaptive: Max. Heating Flow Temperature z2
|
||||
|
||||
Next job is to use temperature readings from more accurate sensors.
|
||||